Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
BMC Ophthalmol ; 24(1): 112, 2024 Mar 07.
Artigo em Inglês | MEDLINE | ID: mdl-38454351

RESUMO

INTRODUCTION: Severe congenital ptosis poses a complex challenge for oculoplastic surgeons, requiring meticulous surgical intervention to restore eyelid function and improve aesthetic outcomes mainly by using frontalis sling approach. A crucial issue in frontalis sling surgeries is the sustainability of effect. PURPOSE: This retrospective study reports the outcomes of two surgical techniques for treating severe congenital ptosis in the paediatric age group: Silicon rods ptosis sling and a novel technique involving the use of Silicon rods with green braided polyester (Ethibond) sutures to secure the rods in place "sling for the sling". METHODS: The medical records of children who underwent frontalis suspension were reviewed in a retrospective fashion. We identified two groups; the first group (20 patients: 35 eyelids) had the traditional frontalis suspension surgery using silicone suspension set, the second group (14 patients: 25 eyelids) was operated using the new "sling for sling" technique. We used the postoperative marginal reflex distance-1 (MRD-1) as the primary outcome measure while the frequency of both wound related complications and recurrence were considered as secondary outcome measures. Post operative data were collected and compared after 1 month, 6 months, 12 months, and 18 months. RESULTS: Preliminary results indicate promising outcomes for both techniques, with significant improvement in eyelid elevation observed in both groups. However, the novel technique using Silicon rods with Ethibond sutures demonstrated enhanced sustainability, leading to a more durable outcome with significantly less recurrence. CONCLUSION: This study highlights the potential benefits of the novel technique in treating severe congenital ptosis and introduces an innovative approach to Silicone rods fixation to achieve a long-term corrective effect.


Assuntos
Blefaroplastia , Blefaroptose , Criança , Humanos , Blefaroplastia/métodos , Estudos Retrospectivos , Silício , Técnicas de Sutura , Blefaroptose/cirurgia , Blefaroptose/congênito , Silicones , Músculos Oculomotores/cirurgia , Resultado do Tratamento
2.
BMC Ophthalmol ; 24(1): 22, 2024 Jan 16.
Artigo em Inglês | MEDLINE | ID: mdl-38229008

RESUMO

AIM: to assess the outcomes of a novel algorithm for the calculation of the amount levator muscle plication in congenital blepharoptosis surgery. METHODS: this retrospective comparative study included 34 patients with congenital ptosis subjected to levator muscle plication surgery during the period from October 2021 to November 2022. They were divided into two groups. Group A: the amount of levator muscle plication was calculated by a traditional formula [(amount of ptosis x 3) + 9 mm in cases with good levator function or (amount of ptosis x 3) + 11 mm in cases with fair levator function]. Group B: the amount of levator muscle plication was calculated by a novel nomogram [the result of the traditional formula was modified by subtracting 4 mm if the calculated amount was ≥ 15 mm or subtracting 3 mm if the calculated amount was < 15 mm]. Demographic data, baseline ptosis characteristics and postoperative results at 1st week, 1st month, 3rd month and 6th month were compared between the groups. Primary outcome measure was postoperative Marginal Reflex Distance (MRD1). Secondary outcome measures were lid contour, lid crease and any reported complications. RESULTS: Group A included 20 eyes of 18 patients while Group B included 20 eyes of 16 patients. The mean amount of levator muscle plication was 16.98 ± 2.44 mm and 13.48 ± 2.42 mm in group A and group B respectively. The difference between the two groups was highly statistically significant (p < 0.001). Mean MRD1 at the 1st postoperative week was 4.95 ± 0.37 mm in group A and 4.08 ± 0.64 mm in group B. This difference was highly statistically significant (P < 0.001). Overcorrection was seen in 8 (40%) eyes in group A and 1 (5%) eye in group B. The difference was statistically significant between the two groups (p = 0.008). Undercorrection was seen in only 1 (5%) eye in group B. No other complications were reported. Surgical success was achieved in 12 (60%) eyes in group A versus 18 (90%) eyes in group B. The difference between the two groups was statistically significant (p = 0.03). CONCLUSION: our novel nomogram for the calculation of the amount levator muscle plication in congenital blepharoptosis surgery is effective in achieving a satisfactory postoperative MRD1.


Assuntos
Blefaroplastia , Blefaroptose , Humanos , Blefaroptose/cirurgia , Blefaroptose/congênito , Pálpebras/cirurgia , Blefaroplastia/métodos , Estudos Retrospectivos , Músculos Oculomotores/cirurgia , Algoritmos , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...